Relay and SIM800 GSM/GPRS Modem based SMS Controlled Wireless Home Automation System with Mobile Number Authentication and Auto Reply using ATmega32

628
Mark as Favourite

In this project, we will learn how to make a Relay and SIM800 GSM/GPRS Modem based SMS Controlled Wireless Home Automation System with Mobile Number Authentication and Auto Reply using AVR ATmega32 Microcontroller. Here, we will control home appliances i.e 2 bulbs and 2 fans wirelessly using SIM800 GSM/GPRS modem and ATmega32 microcontroller. The home appliances are controlled by sending SMS to the SIM800 GSM/GPRS modem of the Home Automation System and the change in status of the home appliances are displayed in a 16X2 alphanumeric LCD and if the control SMS is executed successfully, then the Home Automation System sends a reply SMS bearing changed state of the home appliance as message through the SIM800 GSM/GPRS modem to notify the user that the last control SMS has been successfully executed. But SMS received from one particular mobile number are valid and processed by the Home Automation System and others are discarded.

When the SIM800 GSM/GPRS modem power is turned on, the ATmega32 microcontroller reads the initial status data sent by the SIM800 GSM/GPRS modem through USART protocol. After reading the status data, the ATmega32 microcontroller processes the SIM800 GSM/GPRS modem status data and displays the status of the modem and SIM in the alphanumeric LCD. If SIM card is not present, then "Plz Insert SIM" is displayed, if SIM card is present and modem is ready, then "SIM800 is Ready" is displayed and for other conditions, "SIM800 Error" is displayed in the alphanumeric LCD.

Now, when the SIM800 GSM/GPRS modem is ready, the LCD displays "Send Ctrl SMS:" in 1st row and "All APPli. OFF  " in the 2nd row(As all the appliances are in off state initially). The Home Automation System waits for the control SMS to turn On/Off the home appliances. The control SMS are predefined sets of strings(Message of SMS). The predefined set of strings(Message of SMS) to control the home appliances are shown below:-

Control SMS Home Appliance Status
A1 ON Bulb 1 On
A1 OFF Bulb 1 Off
A12ON Bulb 2 On
A2 OFF Bulb 2 Off
A3 ON Fan 1 On
A3 OFF Fan 1 Off
A4 ON Fan 2 On
A4 OFF Fan 2 Off
ALL ON All Appliances On
ALL OFF All Appliances Off

When the SIM800 GSM/GPRS modem receives any SMS, it sends new SMS notification to the ATmega32 microcontroller. The ATmega32 microcontroller reads the new SMS notification and displays "New Ctrl SMS" in the alphanumeric LCD. But if the ATmega32 microcontroller receives some other notification(other then SMS like Call and others), then "Unknown Error" is displayed in the  alphanumeric LCD.  After receiving new SMS notification, the ATmega32 microcontroller will read the SMS from the SIM800 GSM/GPRS modem memory. If it reads the SMS successfully, then it will compare the mobile number from where SMS is received with the stored mobile number else it will display"Empty location" when the read memory location is empty and "Error" when there is error in reading the SMS. When the control SMS is read successfully, the ATmega32 microcontroller compares the mobile number from where SMS is received with the stored mobile number, if the mobile numbers matches then "Valid Number" is displayed in the alphanumeric LCD and the message of the received control SMS is compared with the predefined ones else "Invalid Number" is displayed in the alphanumeric LCD and SMS is discarded. The mobile number of the received SMS is compared with the stored mobile number each time the Home Automation System receives a SMS and SMS received from valid mobile number are processed by the ATmega32 microcontroller and others are discraded. The ATmega32 microcontroller compares the message of the received control SMS with the predefined ones, if received control SMS matches with any of the predefined strings, then the microcontroller sends the required control signal to the Relay driver to turn On/Off the home appliance and it displays the new status of the home appliance in the alphanumeric LCD. But if the received control SMS does not matches with any of the predefined strings, then "Invalid SMS" is displayed in the alphanumeric LCD. For all control SMS received by the Home Automation System, the Home Automation System sends a reply SMS to the mobile number from where the control SMS is received through the SIM800 GSM/GPRS modem. The reply SMS contains changed state of the home appliance as message if the last SMS received is a valid control SMS and reply SMS contains "Invalid SMS" as message if last SMS received is an invalid SMS. The reply SMS is sent to notify the user about the status of the last SMS processed by the Home Automation System. The status of the SMS sending(like SMS Sending, SMS Sent) are also displayed in the alphanumeric LCD.

Now, send different SMS to the SIM800 GSM/GPRS modem of the Home Automation System from different mobile number and see the change in state of home appliances and check whether auto reply SMS are sent by the Home Automation System or not.

Softwares Required

Hardwares Required

Name Quantity
AVR Trainer Board-100 with ATmega32 1pc
AVR USB Programmer 1pc
SIM800 GSM/GPRS Modem 1pc
RG1602A 16X2 Alphanumeric LCD Green 1pc
Quad Relay Driver 1pc
Home Appliance Board 1pc
12V, 2A SMPS Adaptor 1pc
10 to 10 FRC Female to Female Connector 2pc
1 to 1 Connector-Female to Female 11pc

Circuit Diagram

Video

Downloads

Relay and SIM800 GSM/GPRS Modem based SMS Controlled Wireless Home Automation System with Mobile Number Authentication and Auto Reply using ATmega32